THERM-X HOME

Get your patients colder faster with the most effective cold compression product on the market. The Therm-X can deliver single cycle temperatures as cold as 34 degrees (as cold as any ice machine). If continuous cold is needed the Therm-X can be set to 40 degrees, colder than any of its thermoelectric competitors.

The Therm-X allows for either intermittent compression, or static if you are looking for a more intense edema reduction. A password can be engaged to prevent the patient from changing protocol settings.

Want more details about the Therm-X HOME?

Where can I get a Therm-X HOME?

Get Colder Faster. No Ice Required.

COLDER THAN MOST - EVEN ICE MACHINES!

The temperature you want is the temperature you get. With digital control, you can set a specific temperature and repeat it cycle after cycle, unlike Ice Machines that lose their cool as the ice melts.

WHY NOT WARM UP TOO?

Because the Therm-X is digitally driven, it can get hot as well as cold. Use the Therm-X when your protocol requires heat. No ice machine can do that! The Therm-X eliminates the need for hot packs, cold packs, and ice.

COMPRESSION = CONTACT

Aside from compression’s clinical benefits, compression enhances thermal transfer. The Therm-X has five compression settings that ensure the Garment’s thermal zone stays in contact with the patient to deliver therapeutic temperatures.

"best modality of its kind that we have seen..."

Intuitive touch screen with pre-programmed or customized protocols.

Easy fill tank uses distilled water and isopropyl alcohol. Does not require constant refilling and cleaning, like an ice machine.

THERM-X HOME SPECIFICATIONS

Catalog NUMBER
TX0300

SIZE
10″ x 9″ x 15″

WEIGHT
~ 14 lbs.

Coolant Tank Capacity
400 ml

Coolant Formulation
90% Distilled Water, 10% Isopropyl Alcohol

Power Supply
100V AC – 240V AC, 50/60 Hz

Umbilical Hose
5′ Long with 3-in-one Machine Connector and 3 Garment Connectors

Default Cold Settings
34°F, 45°F, 55°F

Continuous Cycle Cold Settings

40°F – 55°F

Default Heat Settings
105°F, 107°F, 110°F

Continuous Cycle Heat Settings
105°F – 107°F

Non Continuous Cycle Length
Default 10 or 20 minutes, Customizable to 3–40 minutes 

Continuous Cycle (runs indefinitely)
Active: 10–40 minutes, Rest: 30–60 minutes

Garment Edema Pressures
0, 5, 20, 45, and 70 mm Hg
(light, low, medium, and high)

Calf DVT Pressure Range
50 – 70 mm Hg

Foot DVT Pressure Range
90 – 120 mm Hg

Preset Protocols
3 Preset treatment selections and one customizable preset.

HOME Garments
HOME Accessories

Curious how Therm-X therapy works?